For Windows event 4625 with logon type 3, start on the computer that recorded the failed network logon. Read the target account, workstation or source address, and raw Status and SubStatus. Compare nearby 4624 and 4740 records in UTC, then give the Windows or service owner the evidence and one question they can answer.
A common collector can make events from four computers look as though they came from one. This walkthrough uses illustrative Windows Server 2022 sample events to show which failures belong together, why a nearby success that looks like a retry but isn't leaves the original failure open, and how to report a lockout whose caller is unknown.
Contents
Identify where the failure was recorded
For event 4625, logon type 3 means a network logon was attempted on the computer that wrote the Security event. Open the full document for the failed record and find winlog.computer_name. Compare it with System/Computer in the original Windows XML. In the worked example, APP-A recorded the failure. COLLECTOR-LAB is the host running Winlogbeat. A search showing only the collector hostname can mask where the failure was recorded. Microsoft’s event 4625 reference · Elastic’s Winlogbeat field reference.
Check the origin, forwarder, account and network source
Use an existing Security record and its forwarded copy for the source-field check. Match the event ID, event time, original computer and, where preserved, the record ID. Expand the document in Discover to check the indexed values side by side. Winlogbeat can include the XML as event.original when include_xml is enabled for the event log. If it is unavailable in the index, use the Details XML from the source record or a trusted export. The documented collection path ships Windows Security events to the Logstash input and makes them visible in OpenSearch Dashboards. Winlogbeat integration · Windows event log shipping guide.
TargetUserName and TargetDomainName in a 4625 describe the account supplied in the failed attempt. Read the two together because names can recur across local and domain accounts. The Subject fields describe the context that reported the failure. The source workstation and IP are clues to where the attempt came from. If you have both, compare them with inventory or address assignment records for that time. A blank or dash in either field leaves that piece of evidence unknown. The source port can help match a particular connection in other logs. It can change between retries.
If winlog.computer_name is missing or differs from the XML, record the discrepancy and use the original System/Computer for the handoff. If the original is unavailable and the index name is all you have, leave the origin unconfirmed. Preserve a workstation and address that disagree as separate observations. A shared address, proxy or stale inventory entry can leave several possible sources for the same attempt.
A type 5 failure on APP-B points to a service logon associated with Service Control Manager on that host. Check its existing service and System logs for a service name and account at the time of the failure. In this example data, the caller process path ends in services.exe and the network address is unavailable. For the type 3 failure on APP-A, use the recorded workstation JOB-A and the source address to look for a matching application or scheduled job. Windows records the attempted logon type in both cases. The service or application behind a network attempt needs corroboration. Windows logon types and process fields.
The hand-labelled field map below pairs selected XML values with the Winlogbeat 8.19.0 fields used in this example. The example records keep the raw event data, including LogonType as a string. Elastic’s optional Security ingest pipeline can also derive a label such as Network in winlog.logon.type. Check what your own index contains. See the Winlogbeat 8.19 field reference.
| Evidence | Raw Windows XML | Mapped field and sample value |
|---|---|---|
| Event and time | System/EventID and TimeCreated/@SystemTime | event.code = "4625", @timestamp = 2026-11-20T10:14:02Z |
| Recording host and record | System/Computer and EventRecordID | winlog.computer_name = APP-A, winlog.record_id = 8101 |
| Forwarder | Added by the shipping agent | agent.name = COLLECTOR-LAB in this example |
| Account supplied to 4625 | TargetDomainName and TargetUserName | winlog.event_data.TargetDomainName = CONTOSO-LAB, winlog.event_data.TargetUserName = svc-checkout |
| Network evidence | LogonType, WorkstationName and IpAddress | Under winlog.event_data, LogonType = "3", WorkstationName = JOB-A, IpAddress = 192.0.2.31 |
| Failure codes | Status and SubStatus | winlog.event_data.Status = 0xC000006D, winlog.event_data.SubStatus = 0xC000006A |
| Caller on 4740 | TargetDomainName is empty in the 4740 XML | winlog.event_data.TargetDomainName is absent in the mapped example. Caller is unknown. |
Read Status and SubStatus together
Preserve the raw hex values
Copy the two hexadecimal strings into the timeline as recorded, along with any rendered failure reason. Both 4625 examples have Status 0xC000006D, a general logon failure covering a bad username or invalid authentication information. Windows may render these codes in upper or lower case; 0xC000006A and 0xc000006a are the same value. The SubStatus changes the next check. Read it from winlog.event_data.SubStatus in this example data, and check the source XML if your pipeline exposes only translated text. Microsoft’s event 4625 Status and SubStatus definitions.
- Wrong password,
0xC000006A. For the network failures recorded byAPP-A, ask whether the job onJOB-Ais using the current credential reference for the intended account. A recent rotation is a lead to verify against the change record and application logs. - Unknown user,
0xC0000064. For the service failure recorded byAPP-B, check the spelling and account scope in the service configuration. The attempt suppliedAPP-B\svc-checkout, a local account name in this example. The identically named domain account is visible in other rows.
When one value is absent in the forwarded document, compare with the original and mark that value unknown if it is also unavailable there. A literal 0x0 is a value to preserve. Even if the SubStatus is unavailable, a present Status can still narrow the investigation. With only the general 0xC000006D, both the account identifier and the credential reference remain worth checking. Record the visible failure reason as supporting context and keep the code fields available for the Windows owner.
Build the account timeline
Compare successes and lockouts in a bounded UTC window
Anchor on the first 4625 you are investigating. For this example data, start five minutes either side of 2026-11-20T10:14:02Z. In Discover, use an index pattern that includes the relevant Windows Security records and uses @timestamp for event time. Set the time picker to cover the absolute UTC interval below, then use this DQL filter for a saved search. It only reads records. Saving the search stores the search definition. Forwarded Security events often arrive in the ForwardedEvents channel rather than Security. Logit's Winlogbeat configuration reads ForwardedEvents and tags them as forwarded, and the Windows event log shipping guide filters on that channel. Include both channels, or you will miss collector-forwarded rows. You can also filter on the Security Auditing provider name plus the event code:
winlog.provider_name: "Microsoft-Windows-Security-Auditing"
Check the field type in the index pattern for winlog.channel and event.code; use the .keyword subfield if a field is text. Under the example mapping, both fields are keywords with string values. OpenSearch Dashboards query syntax · Winlogbeat 8.19 ECS field definitions.
winlog.channel: ("Security" OR "ForwardedEvents")
AND event.code: ("4625" OR "4624" OR "4740")
AND @timestamp >= "2026-11-20T10:09:02Z"
AND @timestamp <= "2026-11-20T10:19:02Z"
Sort by @timestamp ascending. Add the recording computer, record ID, target name, source workstation and address as columns, and inspect the relevant domain and SID fields inside each row. Keep the exact UTC bounds in the ticket. This search selects all five example rows, including the success on a different host and the lockout with a blank caller. If an expected row is missing, check the channel filter, the time field and timezone, Security audit coverage, forwarding subscription and whether the relevant host’s logs reached the index. The collection scope matters especially for domain controllers. If a repeat interval or known clock offset extends beyond the first window, widen it and record the new bounds. With an uncertain clock offset, keep close cross-host ordering provisional.
| UTC on 20 November 2026 | Recording host and record ID | Event and evidence | Association with the first failure |
|---|---|---|---|
| 10:14:02Z | APP-A / 8101 | 4625 type 3. CONTOSO-LAB\svc-checkout from JOB-A / 192.0.2.31. SubStatus 0xC000006A. | Anchor |
| 10:14:09Z | APP-C / 7301 | 4624 type 3. Same domain account from JOB-B / 192.0.2.44. | Unrelated. Same account seven seconds later, with a different source and destination. |
| 10:14:19Z | APP-A / 8102 | 4625 type 3. Same supplied domain account, source and failure codes. A different record ID and source port. | Supported. A second recorded failure on the same path. |
| 10:14:23Z | APP-B / 9101 | 4625 type 5. Supplied local account APP-B\svc-checkout. SubStatus 0xC0000064. | Unrelated. Different account scope and logon path. |
| 10:14:42Z | DC-LAB / 12001 | 4740. Target is svc-checkout. Caller computer unknown. | Ambiguous. The target SID identifies the domain account in the example inventory. The link to the APP-A attempts is unresolved. |
A 4624 records a session on the destination computer. To associate one with a 4625, compare the supplied account and realm, a usable target SID where available, logon type, destination computer, workstation or address, and event time. The authentication package or an application request ID can add context if both records can be traced to the same path. A 4625 may carry a null target SID, as these failures do. Treat that SID as unavailable for identity matching. If two records have a usable logon ID for the same session and field role, scope that comparison to the same computer. Record IDs identify individual log entries within their log context. Matching IDs on different hosts carry no such association. Microsoft’s event 4624 field reference.
The success that looks like a retry but isn't is the 4624 on APP-C. An account-and-time search would make it look like a successful retry. In this example data, a separate workload on JOB-B accessed APP-C. The same account succeeded on that path and subsequently failed again on the original path from JOB-A to APP-A. Keep the success in the timeline as context and leave recovery of the original network logon unresolved. Look for a later success on the original path, backed by the service’s own record of a successful operation.
The 4740 confirms that DC-LAB recorded a lockout. In the Microsoft XML example, the field named TargetDomainName carries the Caller Computer Name for this event. It is blank in this example data. Match the locked account using TargetSid against a trusted directory record or the usable TargetUserSid from a 4624. To examine possible contributions to the lockout, check the other relevant domain controller records. For NTLM, a 4776 can contribute the validation result and source workstation. For Kerberos, a 4771 can contribute the target account, client address and failure code if pre-authentication failed. Compare those fields with destination Security logs and existing job or service logs. Record any corroborated candidate source in the ticket separately and leave the blank 4740 caller unknown. Event 4740 · Event 4776 · Event 4771.
For this timeline, ask the directory owner to check for NTLM validation failures for the same account and source workstation during the window, starting with the controllers that handled the account’s authentication. A 4776 with the right workstation gives you another source observation. Check the destination against the Security or application record on APP-A. If the validation record points elsewhere, keep that source as an alternative and attach the supporting record reference.
If the service desk and Windows team need a common place to review forwarded events, see the Logit.io Event Log Analyser.
Choose the owner with the available evidence
Group failures and document alternate sources
Start with a per-account count of 4625 events in the same UTC window. Use both the target domain or local host scope and the supplied name. The read-only search below uses a multi_terms aggregation. Run it in OpenSearch Dashboards Dev Tools against your stack's Logs index pattern. The example uses *-*, which is the pattern shown in Logit's alerting docs; replace it if your stack uses a narrower pattern. Check the field type in the index pattern for the term filters on winlog.channel and event.code, and for the aggregation fields; use the .keyword subfield if a field is text. Keep failures with an unknown account or scope visible in the timeline and review those separately from these buckets. OpenSearch multi-terms aggregation reference.
GET /*-*/_search
{
"size": 0,
"query": {
"bool": {
"filter": [
{ "bool": { "should": [
{ "term": { "winlog.channel": "Security" } },
{ "term": { "winlog.channel": "ForwardedEvents" } }
], "minimum_should_match": 1 } },
{ "term": { "event.code": "4625" } },
{ "range": { "@timestamp": {
"gte": "2026-11-20T10:09:02Z",
"lte": "2026-11-20T10:19:02Z"
} } }
]
}
},
"aggs": {
"failures_by_account": {
"multi_terms": {
"terms": [
{ "field": "winlog.event_data.TargetDomainName" },
{ "field": "winlog.event_data.TargetUserName" }
]
}
}
}
}
Expect two documents for CONTOSO-LAB\svc-checkout and one for APP-B\svc-checkout. Check that the rows within each bucket represent distinct records before treating the count as repeated failures. If collection paths overlap, compare the origin, channel, record ID and event time. For threshold-based triage, the Logs frequency rule counts matching events in a window and can group by query_key. Within a single known account domain, you would group by the mapped user name field:
winlog.event_data.TargetUserName
That grouping would yield two matching 4625 rows for the domain account in this example. The count cannot establish event order, intent or who initiated the attempts. Logs frequency rule reference.
Route the repeated type 3 failures to the team that owns the source workload if inventory and application evidence support that lead. In this example the service inventory lists a Checkout Reconciliation job on JOB-A that uses the domain account to access APP-A. Send the type 5 record to the Windows service owner for APP-B to review its local account configuration. If multiple workloads share the source address or the inventory conflicts with the observed hostname, add the alternative sources and ask the Windows or identity owner to review the evidence. Give them the same UTC window and record references. A 4625 establishes a failed logon attempt and the supplied account name. Establishing compromise or attributing it to a person requires independent evidence.
This illustrative service-desk ticket can be pasted into a case with the timeline attached.
Route to Checkout Reconciliation service owner
Window 2026-11-20 10:09:02Z to 10:19:02Z
Account CONTOSO-LAB\svc-checkout
10:14:02Z | APP-A Security 8101 | 4625 type 3 from JOB-A / 192.0.2.31.
10:14:09Z | APP-C Security 7301 | Unrelated 4624, from JOB-B / 192.0.2.44.
10:14:19Z | APP-A Security 8102 | Same type 3 path and failure codes as 8101.
10:14:23Z | APP-B Security 9101 | Separate type 5 failure for APP-B\svc-checkout.
10:14:42Z | DC-LAB Security 12001 | 4740. Caller unknown. Cause unresolved.
APP-A failure codes | Status 0xC000006D, SubStatus 0xC000006A.
Service inventory lists the JOB-A job using this account against APP-A.
Can you confirm which credential reference the JOB-A job used at 10:14Z?
Frequently asked questions
Logon type 3 and the service
Type 3 identifies a network logon. To find the service or resource, compare the destination computer and reported source with logs for the workload that was active at that time. In this example data, the service inventory gives the owner a specific job to check.
A blank 4740 caller
A blank caller means the caller is unknown. Record the computer that wrote the 4740 and the locked account SID. A validation event or application log may support a candidate source, which belongs in the ticket with its own evidence.
The free trial
The Logit.io free trial includes every feature, including alerting and Hosted OpenSearch MCP. Hosted OpenSearch MCP works with any MCP client that supports a remote HTTPS connection and a custom Authorization header. Logit.io trial information · Hosted OpenSearch MCP requirements.
Next steps
Check one forwarded 4625 against its source XML, save the bounded UTC search in Discover, and attach the labelled timeline to the handoff. Include the target account, the recording computer, the observed caller evidence and one question for the owner. If the owner finds a matching service record, add its timestamp and reference so the next reviewer can follow the same evidence.
Unlock complete visibility with hosted ELK, Grafana, and Prometheus-backed Observability