To see which process started on a Windows machine, what it connected to and which files and Run keys it wrote, run Sysmon with a config that logs event IDs 1, 3, 11, 13 and 22, then ship the Sysmon/Operational channel with Winlogbeat and use the output block from the Logit.io Winlogbeat integration page unchanged. Logit.io's Windows Sysmon Dashboard Library pack reads the processed fields in winlogbeat-* across eight dashboards. Before you trust a panel, open one event in Discover and check that it has event.module: sysmon and a process.name.
This guide takes one Windows host from a Sysmon config to a working investigation. You'll install Sysmon with rules that fill every panel, add the channel to Winlogbeat, prove each event type arrives with the right fields, install the pack, then follow an encoded PowerShell start through its DNS lookup, outbound connection, dropped file and Run key. Dashboard images use the pack's demonstration data. Hosts, users, addresses and command output in the examples are illustrative.
Contents
- What Sysmon adds to the Windows logs you already ship
- How a Sysmon event becomes dashboard fields
- Install Sysmon with a config that fills the panels
- Point Winlogbeat at the Sysmon channel
- Prove each event type before you install the pack
- Install the Windows Sysmon pack
- Worked example: an encoded PowerShell start from a mail client
- Registry and file changes worth a second look
- Searches and alerts to keep beside the dashboards
- When panels stay empty or counts look wrong
- What Sysmon costs and what it can't see
- Keep the endpoint evidence next to the rest of your logs
- Frequently asked questions
- Next steps
What Sysmon adds to the Windows logs you already ship
The Security log tells you who signed in and when an account changed. It says much less about what ran after the sign-in. Sysmon is a Microsoft Sysinternals service and driver that writes its own channel, Microsoft-Windows-Sysmon/Operational, with one event per process start, network connection, file creation, registry write, DNS query and a handful of rarer actions. Each event carries a process GUID, so a start, the connection that process made and the file it wrote can be tied back together later.
That GUID is the reason Sysmon is worth the extra volume. A single alert on an encoded PowerShell command tells you very little. The same alert plus the parent that launched it, the name it resolved, the address it reached and the executable it dropped tells you whether to close the ticket or isolate the machine. The Windows Sysmon pack is built around those questions, and every panel reads a field that comes from one of these event IDs:
| Event ID | What Sysmon records | Fields the pack reads | Dashboard |
|---|---|---|---|
| 1 | Process start, with command line, hashes, parent and integrity level | process.name, process.parent.name, process.args, winlog.event_data.IntegrityLevel | Process starts, PowerShell launches |
| 3 | TCP or UDP connection, with the process that made it | destination.ip, network.transport, process.name | Network connections |
| 22 | DNS query and its answers, per process | dns.question.name, dns.resolved_ip | DNS queries |
| 11, 15 | File created, and alternate data streams such as Zone.Identifier | file.path, file.extension | Registry and file changes |
| 12, 13, 14 | Registry key or value created, deleted, set or renamed | registry.path, registry.value | Registry and file changes |
| 6, 8, 9 | Driver loaded, remote thread created, raw disk read | winlog.event_data.Signed, winlog.event_data.TargetImage, file.path | Injection, raw disk and drivers |
The other two dashboards span all of them: Windows Sysmon activity is the overview, and host investigation is a single timeline you filter by host, user or process. All eight open on the last 24 hours with a 60-second refresh.
How a Sysmon event becomes dashboard fields
Winlogbeat 7.x ran a JavaScript module on each Windows host to rename Sysmon's fields. From 8.0 that processing moved into ingest pipelines, so Winlogbeat 8.x and 9.x send the raw event: everything Sysmon wrote sits under winlog.event_data with Sysmon's own names, such as Image, ParentImage and DestinationIp. The Sysmon module pipeline turns those into the fields the dashboards query. On Logit.io that pipeline runs on your stack after Logstash receives the event, so nothing extra is needed in winlogbeat.yml beyond the integration page's config.
The Sysmon module pipeline fills every field the pack needs, plus a few that matter for investigations: process.entity_id from ProcessGuid, process.parent.entity_id from ParentProcessGuid, user.name without the domain prefix and destination.port as a number.
Two consequences are worth knowing before you build anything on top. First, if the pipeline never runs, events still arrive and are still searchable, but they only have winlog.* fields, no event.module and no process.name, so every panel stays at zero. Second, field types on winlogbeat-* come from the stack's Winlogbeat index template, which is managed: you can read the template but not change it. Most string fields there are plain keyword fields with no .keyword sub-field, so you query process.name directly, and matches are case-sensitive.
Install Sysmon with a config that fills the panels
The Sysmon integration page has a quick install command with no configuration file. It gets events flowing, and it also turns on image-load logging, which is one of Sysmon's noisiest event types and isn't used by any panel. Sysmon's defaults also skip the file and registry events that the registry and file changes dashboard needs. A short config fixes both.
This one logs every process start, outbound connections except loopback, non-Microsoft driver loads, remote threads, raw disk reads, files created in the usual drop locations, Run key and EULA writes, alternate data streams on downloads and DNS queries apart from reverse lookups. It doesn't filter event IDs 2 (file creation time changes) or 5 (process terminates), so Sysmon logs those by default. Treat it as a starting point and add exclusions for your own noisy software rather than removing whole event types:
<!-- sysmon-logit.xml: a starting point that fills every Windows Sysmon panel.
Print the newest schema your binary supports with: Sysmon64.exe -s -->
<Sysmon schemaversion="4.82">
<HashAlgorithms>SHA256,IMPHASH</HashAlgorithms>
<EventFiltering>
<!-- Event 1: every process start (an empty exclude list logs everything) -->
<RuleGroup name="process-starts" groupRelation="or">
<ProcessCreate onmatch="exclude" />
</RuleGroup>
<!-- Event 3: network connections, minus loopback -->
<RuleGroup name="network" groupRelation="or">
<NetworkConnect onmatch="exclude">
<DestinationIp condition="is">127.0.0.1</DestinationIp>
<DestinationIp condition="is">::1</DestinationIp>
</NetworkConnect>
</RuleGroup>
<!-- Event 6: driver loads, minus drivers signed by Microsoft -->
<RuleGroup name="drivers" groupRelation="or">
<DriverLoad onmatch="exclude">
<Signature condition="contains">Microsoft</Signature>
</DriverLoad>
</RuleGroup>
<!-- Event 8: remote threads -->
<RuleGroup name="remote-threads" groupRelation="or">
<CreateRemoteThread onmatch="exclude" />
</RuleGroup>
<!-- Event 9: raw disk reads -->
<RuleGroup name="raw-disk" groupRelation="or">
<RawAccessRead onmatch="exclude" />
</RuleGroup>
<!-- Event 11: files created where droppers like to land -->
<RuleGroup name="file-creates" groupRelation="or">
<FileCreate onmatch="include">
<TargetFilename condition="contains">\AppData\Local\Temp\</TargetFilename>
<TargetFilename condition="contains">\Downloads\</TargetFilename>
<TargetFilename condition="contains">\Start Menu\Programs\Startup\</TargetFilename>
<TargetFilename condition="begin with">C:\Users\Public\</TargetFilename>
<TargetFilename condition="end with">.ps1</TargetFilename>
</FileCreate>
</RuleGroup>
<!-- Events 12, 13 and 14: autostart keys and Sysinternals EULA flags -->
<RuleGroup name="registry" groupRelation="or">
<RegistryEvent onmatch="include">
<TargetObject condition="contains">\CurrentVersion\Run</TargetObject>
<TargetObject condition="end with">\EulaAccepted</TargetObject>
</RegistryEvent>
</RuleGroup>
<!-- Event 15: alternate data streams on downloads (Zone.Identifier) -->
<RuleGroup name="streams" groupRelation="or">
<FileCreateStreamHash onmatch="include">
<TargetFilename condition="contains">\Downloads\</TargetFilename>
</FileCreateStreamHash>
</RuleGroup>
<!-- Event 22: DNS queries, minus reverse lookups -->
<RuleGroup name="dns" groupRelation="or">
<DnsQuery onmatch="exclude">
<QueryName condition="end with">.arpa</QueryName>
</DnsQuery>
</RuleGroup>
</EventFiltering>
</Sysmon>
We checked this config against Sysmon's schema but not on every Windows build; load it on one test host first and confirm the rules with Sysmon64.exe -c.
Download Sysmon from Microsoft Sysinternals (v15.22 at the time of writing). The schema version in the example is the one Microsoft's own sample config uses; Sysmon64.exe -s prints the newest schema your binary supports if you want to use rule options added since. Then install or update from an elevated prompt:
# Elevated PowerShell on the Windows host, in the folder holding Sysmon64.exe and sysmon-logit.xml
cd 'C:\Program Files\Sysmon'
# New install with the config
.\Sysmon64.exe -accepteula -i .\sysmon-logit.xml
# Already installed (for example with the quick command on the integration page)?
# Replace the running config instead of reinstalling
.\Sysmon64.exe -c .\sysmon-logit.xml
# Print the active config to confirm which rules loaded
.\Sysmon64.exe -c
# Give the Sysmon channel room to hold a few hours of events if Winlogbeat stops
wevtutil sl Microsoft-Windows-Sysmon/Operational /ms:536870912
The last line matters more than it looks. Winlogbeat reads the channel from where it left off, so a short Winlogbeat outage costs nothing as long as the events are still in the log. If the channel is small and busy, Windows overwrites the oldest events before Winlogbeat gets back to them, and those events are gone for good.
Point Winlogbeat at the Sysmon channel
If Winlogbeat already ships Application, System or Security from this host, add the Sysmon channel to the same config; you don't need a second agent. If this is the first Winlogbeat you're installing, First Windows Event Logs with Winlogbeat on Logit.io covers the stack, the install and the first Discover search. The full config, with your stack's Logstash host and port filled in, is on the Winlogbeat integration page. The parts that matter for Sysmon look like this:
###################### winlogbeat.yml (Winlogbeat 8.15.2 or 9.1.0) ######################
# Start from the config on your stack's Winlogbeat page: it fills in the real Logstash
# host and port. Keep its output block exactly as shown there.
winlogbeat.event_logs:
- name: Microsoft-Windows-Sysmon/Operational
ignore_older: 72h # don't backfill weeks of history on the first start
tags: [sysmon]
# keep the other channels you already ship (Application, System, Security ...)
output.logstash:
hosts: ["your-logstash-host:your-ssl-port"]
loadbalance: true
ssl.enabled: true
pipeline: "winlogbeat-%{[agent.version]}-routing"
processors:
- add_host_metadata:
when.not.contains.tags: forwarded
- add_cloud_metadata: ~
ignore_older stops the first start from shipping weeks of history in one burst. Keep the output block as the integration page shows it. If you've copied a config written for the 7.x module with a script processor, remove that processor: the 7.x script file doesn't exist in 8.x and 9.x installs. The differences that matter when you move a host from 8.x to 9.x are in Winlogbeat 8 vs 9 migration on Logit.io.
Check the file and the connection before restarting the service:
# Elevated PowerShell in the Winlogbeat install folder
.\winlogbeat.exe test config -c .\winlogbeat.yml -e
.\winlogbeat.exe test output -c .\winlogbeat.yml -e
Restart-Service winlogbeat
Get-Service winlogbeat
test config should print Config OK and test output should report a successful connection and TLS handshake to your Logstash endpoint. If test output fails, fix that first; nothing after this point will work without it.
Prove each event type before you install the pack
Installing dashboards on data you haven't checked turns every empty panel into a guessing game. Generate a few known events on a test host instead, then find each one. This script causes a process start, a DNS query, an outbound connection, a file in Temp and a Run value that's set and removed straight away:
# Run as a normal user on a test host once Sysmon and Winlogbeat are running.
# Events 1, 22 and 3: a PowerShell start that resolves a name and connects out
powershell.exe -NoProfile -Command "Resolve-DnsName example.com | Out-Null; Invoke-WebRequest -UseBasicParsing https://example.com | Out-Null"
# Event 11: a .tmp file in Temp
Set-Content -Path "$env:TEMP\logit-sysmon-test.tmp" -Value 'sysmon test'
# Event 13, then event 12: set a Run value and remove it again
$run = 'HKCU:\Software\Microsoft\Windows\CurrentVersion\Run'
New-ItemProperty -Path $run -Name LogitSysmonTest -Value 'C:\Windows\System32\notepad.exe' -PropertyType String -Force | Out-Null
Remove-ItemProperty -Path $run -Name LogitSysmonTest
# Confirm Sysmon wrote them locally before you look in OpenSearch Dashboards
Get-WinEvent -LogName 'Microsoft-Windows-Sysmon/Operational' -MaxEvents 200 |
Group-Object Id | Sort-Object Name | Select-Object Name, Count
The last command groups the most recent local Sysmon events by ID. You should see 1, 3, 11, 12, 13 and 22 in the list. If an ID is missing here, the Sysmon config doesn't log it and no amount of dashboard work will help.
Next, open Discover on your stack, select the winlogbeat-* index pattern and set the time range to the last 15 minutes. These three searches tell you most of what you need:
# Every processed Sysmon event
event.module:sysmon
# Your test host, limited to the event types the test script creates
event.module:sysmon and host.name:"your-test-host" and event.code:(1 or 3 or 11 or 12 or 13 or 22)
# Sysmon events that arrived without the module processing (should return nothing)
winlog.channel:"Microsoft-Windows-Sysmon/Operational" and not event.module:sysmon
The first should return events. The second should show each of the test event types for your host; check the spelling of host.name in an expanded event if it returns nothing. The third is the important one: it should return nothing. Any hits there are Sysmon events that arrived without module processing. Expand one of the network events from the test and compare it with this trimmed processed event:
{
"@timestamp": "2026-11-25T08:31:12.000Z",
"agent": { "type": "winlogbeat", "version": "9.1.0" },
"host": { "name": "ws-022" },
"event": {
"module": "sysmon",
"code": "3",
"action": "Network connection",
"category": ["network"]
},
"process": {
"name": "powershell.exe",
"executable": "C:\\Windows\\System32\\WindowsPowerShell\\v1.0\\powershell.exe",
"entity_id": "{3c0ffee0-aaaa-6744-1a02-000000003b00}"
},
"user": { "name": "j.okafor", "domain": "CORP" },
"source": { "ip": "10.20.6.22", "port": 52011 },
"destination": { "ip": "203.0.113.50", "port": 443 },
"network": { "transport": "tcp", "direction": "egress" },
"winlog": {
"channel": "Microsoft-Windows-Sysmon/Operational",
"event_id": "3"
}
}
If your event has winlog.event_data.Image and winlog.event_data.DestinationIp but no process.name or destination.ip, the module pipeline didn't run. Check agent.version and that winlogbeat.yml has no 7.x script processor, then contact support with one expanded event before you change anything else. If you've enabled the dead letter queue (Enable DLQ under Advanced Stack Settings), events that Logstash couldn't index at all, for example because of a field type conflict, go to the stack's Logstash dead letter queue rather than being dropped.
Install the Windows Sysmon pack
Open the Dashboard Library from the links at the bottom of your Logs stack's card. Use Rescan stack if Windows Sysmon doesn't show a Data detected badge yet, then select Select all beside the pack and Install dashboards. Allow a minute or two, then open Logit.io Windows Sysmon activity from Dashboards in OpenSearch Dashboards.
Detection looks back over the last 7 days for Winlogbeat indexes that contain the Sysmon channel or event.module: sysmon, and checks that event.code is aggregatable. Matching on the channel alone means detection is a compatibility hint, not a health check: unprocessed events earn the badge and still leave every panel empty. That's why the Discover check above comes first.
The overview on the pack's demonstration data. Counts are Sysmon events, not processes or sessions; one process can produce dozens of events.
Read the top row from right to left. Last event received is the latest @timestamp in range, so check it first: a zero on any other tile means nothing if the feed stopped an hour ago. The event-types donut is the quickest way to see whether your Sysmon config is doing what you meant. If it shows only 1 and 5, the config isn't logging network, file, registry or DNS events, whatever you thought you installed.
Worked example: an encoded PowerShell start from a mail client
Here's the investigation the pack is built for, using an illustrative chain on a test host called ws-022. Start on Logit.io Windows Sysmon PowerShell launches. The Suspicious PowerShell flags tile counts PowerShell starts whose arguments include an encoded-command switch, an execution-policy bypass or a hidden window. It matches whole tokens in process.args, so -enc counts while a script that merely contains the text "enc" doesn't.
PowerShell launches on demonstration data. Red tiles are above zero; they mark something to read, not a confirmed incident.
The table at the bottom lists each start with its parent, user, integrity level and command line. To get the same rows in Discover, or to widen the net beyond what the tile matches, search for the common spellings of the encoded-command switch:
event.module:sysmon and event.code:1
and process.name:(powershell.exe or pwsh.exe)
and process.args:("-e" or "-en" or "-enc" or "-Enc" or "-ENC" or "-ec" or "-EncodedCommand" or "-encodedcommand")
On ws-022 that returns one start: powershell.exe with -nop -w hidden -enc, parent cmd.exe, medium integrity, user j.okafor. Medium integrity tells you it ran with the user's normal rights, not elevated. The question now is what that process did, and the answer is one field away. Expand the event, copy its process.entity_id and search on it:
# Everything the PowerShell process did (paste its process.entity_id)
event.module:sysmon and process.entity_id:"{3c0ffee0-aaaa-6744-1a02-000000003b00}"
# Processes it started
event.module:sysmon and event.code:1 and process.parent.entity_id:"{3c0ffee0-aaaa-6744-1a02-000000003b00}"
# How it was started: Office parents launching a shell (check the case your hosts report)
event.module:sysmon and event.code:1
and process.parent.name:(OUTLOOK.EXE or WINWORD.EXE or EXCEL.EXE or outlook.exe or winword.exe or excel.exe)
and process.name:(cmd.exe or powershell.exe or wscript.exe or mshta.exe)
The first search returns four events that share one process GUID: the start itself, a DNS query for files.example.net, a TCP connection to 203.0.113.50 on port 443 and a file called stage.exe written to the user's Temp folder. The second returns stage.exe starting as a child of that PowerShell process. Searching on stage.exe's own process.entity_id then shows it setting a value under HKU\...\CurrentVersion\Run, which is how it would come back after a reboot. The third search goes the other way: the PowerShell's parent was cmd.exe, and the cmd.exe start shows OUTLOOK.EXE as its parent.
Notice the capital letters. Sysmon reports the image name as it's stored on disk, and Office binaries usually appear in upper case, so a filter on outlook.exe alone misses them. On real hosts, check the top values for process.parent.name in Discover before you write a filter that depends on case.
You now have a sequence you can act on: mail client, shell, hidden encoded PowerShell, outbound download, new executable, persistence. Use Logit.io Windows Sysmon host investigation with a filter on host.name for the surrounding hour to see what else happened on ws-022, and look up the hash in process.hash.sha256 on the stage.exe start in your threat intelligence tools. None of this proves intent. A software installer launched from an email link can produce a similar chain. What the chain gives you is the evidence to decide quickly.
Registry and file changes worth a second look
The registry and file changes dashboard is the quietest of the eight when the config above is in place, and that's deliberate. It only sees writes to the locations the config includes, so each row is worth reading.
Registry and file changes on demonstration data. The EULA tile is red because it flags first runs of Sysinternals tools, which attackers use as well as admins.
Sysinternals EULA accepted counts writes of the EulaAccepted value. Each Sysinternals tool sets it the first time it runs under an account, so a new PsExec EULA on a server nobody administers interactively is worth a question. Alternate data streams counts Zone.Identifier streams that browsers attach to downloads; the created file types donut counts event 11 only, so streams (event 15) don't appear there; in Discover their file.extension shows as "Identifier". Temporary files created counts .tmp files only, so for executables and scripts in the same folders use the saved searches in the next section.
Searches and alerts to keep beside the dashboards
The dashboards answer the common questions. These searches cover the gaps the dashboards leave, and each is worth saving in Discover:
# Executables, DLLs and scripts written by any process
event.module:sysmon and event.code:11 and file.extension:(exe or EXE or dll or DLL or ps1 or PS1 or bat or BAT)
# Run key writes
event.module:sysmon and event.code:13 and registry.key:*CurrentVersion\\Run*
# LDAP and LDAPS connections, using the port field the module pipeline fills
event.module:sysmon and event.code:3 and destination.port:(389 or 636)
# PowerShell started under another name (OriginalFileName survives a rename)
event.module:sysmon and event.code:1
and process.pe.original_file_name:(PowerShell.EXE or pwsh.dll)
and not process.name:(powershell.exe or pwsh.exe)
# Unsigned drivers
event.module:sysmon and event.code:6 and winlog.event_data.Signed:false
The pack's LDAP connections tile and its renamed-PowerShell fallback read winlog.event_data.DestinationPort and winlog.event_data.OriginalFileName, which the Sysmon module moves on every Winlogbeat version. Until the pack is updated, the LDAP tile reads 0 and renamed copies of PowerShell aren't counted; these saved searches read the fields that are actually filled.
Two alerts give you most of the value without much noise. The first fires on any encoded PowerShell start, grouped per host so one busy machine produces one notification per half hour. The second is a flatline rule that tells you when a host that was sending Sysmon events stops, which is how you find a stopped service or an uninstalled driver:
name: Sysmon encoded PowerShell start
type: frequency
index: winlogbeat-*
num_events: 1
timeframe:
minutes: 5
query_key: host.name
realert:
minutes: 30
filter:
- query:
query_string:
query: 'event.module:sysmon AND event.code:1 AND process.name:(powershell.exe OR pwsh.exe) AND process.args:("-e" OR "-en" OR "-enc" OR "-Enc" OR "-ENC" OR "-ec" OR "-EncodedCommand" OR "-encodedcommand")'
alert:
- "email"
email:
- "[email protected]"
name: Sysmon host gone quiet
type: flatline
index: winlogbeat-*
threshold: 1
timeframe:
minutes: 30
query_key: host.name
forget_keys: true
realert:
hours: 1
filter:
- query:
query_string:
query: 'event.module:sysmon'
alert:
- "email"
email:
- "[email protected]"
Both are standard rules for Logit.io alerting; see creating alerts for where to paste them and how to test them before saving. The flatline rule only knows about hosts it has already seen, so a host that never sent anything won't trigger it; check new hosts in Discover when you roll Sysmon out. If an approved admin script uses encoded commands, exclude it by host or parent in the filter rather than turning the alert off.
When panels stay empty or counts look wrong
| Symptom | What to check | Don't assume |
|---|---|---|
| Data detected, but every panel is empty | Run the unprocessed-events search. Hits mean the module pipeline didn't run: check agent.version and that winlogbeat.yml has no 7.x script processor, then contact support with one expanded event | That the pack queries are wrong |
| Process panels fill, others stay at zero | Sysmon64.exe -c on the host, and the local Get-WinEvent count by ID | That nothing happened on the network |
| LDAP connections tile is zero with LDAP traffic | The LDAP saved search on destination.port | That no process talks to a domain controller |
| A filter misses a process you can see | Case: keyword fields match exactly, and Office binaries often report upper-case names | That the event is missing |
| Exact search on a long command line finds nothing | Command lines over 1,024 characters aren't indexed in process.command_line; search process.command_line.text or process.args | That the start wasn't logged |
| Counts drop after a change window | Search event.code:16 for Sysmon config changes on that host | That activity fell |
| Last event received is hours old | Winlogbeat service state, then the Sysmon channel size | That the zeros are good news |
user.name holds the account name without its domain, so a.patel in two domains looks like one user in the users donut; user.domain separates them. For driver events there's no user at all, which is expected.
What Sysmon costs and what it can't see
Volume is the main cost. Process starts and DNS queries scale with how busy a machine is, so a build server or a terminal server can send many times more Sysmon events than a quiet file server. After a day, use the activity dashboard's event-types and hosts donuts to find the biggest contributors, then add exclusions for known-good images in the config. Exclude by full image path rather than by name, since attackers name things svchost.exe precisely because people exclude it.
Sysmon only sees what its config tells it to log and what happens while its driver runs. Someone with admin rights can stop it, unload the driver or replace the config, and the flatline alert and the config-change search are your signal that this happened. It doesn't see inside encrypted connections, it doesn't record the contents of files it notes, and DNS events only cover lookups that go through the Windows DNS client. Treat it as a strong record of process behaviour, not as an endpoint protection product.
The pack has limits too. It reads Sysmon only, so sign-ins and account changes stay with your Security log views, and it has no geographic map or threat-intelligence lookup. Those are deliberate: an IP address on a connection is evidence to check, not a verdict.
Keep the endpoint evidence next to the rest of your logs
Sysmon is most useful when its events sit beside the firewall, proxy, identity and application logs you already search. Hosted OpenSearch on Logit.io keeps them in one stack, the Dashboard Library gives you the first views without building them, and security analytics covers the wider investigation and retention questions. The free trial has full access to every feature, including the Dashboard Library and alerting, so you can run the whole test in this guide on one machine before rolling Sysmon out.
Unlock complete visibility with hosted ELK, Grafana, and Prometheus-backed Observability
Frequently asked questions
Do I need Sysmon if I already ship the Security log?
They answer different questions. The Security log covers sign-ins, lockouts and account changes. Sysmon covers what processes did: what started what, which addresses and names they reached, and which files and Run keys they wrote. Most teams ship both from the same Winlogbeat.
Why does the pack show Data detected when every panel is empty?
Detection matches the Sysmon channel name as well as event.module: sysmon, so raw events earn the badge. The panels need the processed fields. Run the unprocessed-events search; if it returns hits, the module pipeline didn't run on those events.
Does the pack work with Winlogbeat 7.x?
Yes, with the 7.x sysmon module script on the host, which writes the same ECS fields the 8.x and 9.x pipeline does. On every version, use the saved searches for LDAP connections and renamed PowerShell.
Can I use a community Sysmon config instead of this one?
Yes. Check that it logs event IDs 1, 3, 6, 8, 9, 11 to 15 and 22, then run the test script and the Discover searches. Large community configs often exclude more than you expect, so the event-types donut is worth checking after the first day.
How do I stop one noisy process filling the dashboards?
Exclude it in the Sysmon config by full image path, apply the change with Sysmon64.exe -c and confirm the change with an event.code:16 search. Filtering it out of the dashboards instead still costs you the ingest volume.
Next steps
- Install Sysmon with the config above on one test host and run the test script.
- Confirm the unprocessed-events search returns nothing in Discover.
- Install the Windows Sysmon pack from the Dashboard Library.
- Save the searches above and add the encoded PowerShell and host flatline alerts.
- Roll out to more hosts, then tune exclusions from the event-types and hosts donuts.